Protocol

ARDS

Urgent

Low stretch, higher PEEP, prone, no marathon recruit

Acute (<1 week) bilateral opacities not fully explained by heart failure, PaO2/FiO2 ≤300 on PEEP ≥5.

Example educational pathway · v2026-08-19 · Last content review 2026-08-19

This is a synthesized educational pathway. Verify against current primary sources and your patient’s full clinical context before acting.

Ask Grok about this

Before using: Does this match your patient’s full picture and current primary guidelines? Review the Sources tab and the cited papers.

  1. Volume-control or equivalent, 6 mL/kg predicted body weight

    Plateau ≤30 cm H2O. If plateau is high, drop TV toward 4 mL/kg. Driving pressure (Pplat − PEEP) ≤15 is the nicer target.

    Doses are approximate educational examples based on IBW or total body weight as selected; always confirm with pharmacy and current local formulary.

  2. Higher PEEP without recruitment maneuvers

    ATS 2024 suggests a higher-PEEP strategy for moderate–severe ARDS and strongly recommends against prolonged recruitment maneuvers. Do not PEEP a unilateral pneumonia into the other lung blindly.

  3. Prone if P/F <150 despite optimization

    Start after a short stabilization. Sessions ≥16 consecutive hours. ESICM: strong. ATS: strong for severe.

  4. NMB only for a reason

    ATS 2024: conditional yes for early (<48 h) severe ARDS (P/F ≤100) with dyssynchrony. ESICM 2023: against routine continuous NMB. ROSE was neutral — do not paralyze everyone.

  5. Conservative fluids; steroids are a maybe

    Treat the cause. ATS 2024: conditional corticosteroids in ARDS (not every viral pneumonia). Watch superinfection.

  6. Rescue only after the less-invasive ladder

    Lung-protective vent + higher PEEP + prone ± NMB before VV-ECMO. Inhaled pulmonary vasodilator is a bridge, not a destination.

Calculators

Related

Educational sequence for licensed clinicians. Institutional protocols take precedence.

EDUCATIONAL REFERENCE FOR CLINICIANS ONLY. Not medical advice, not orders, not a medical device, and not a substitute for clinical judgment, local protocols, institutional guidelines, or pharmacist verification. Always independently review the basis for any recommendation. Use at your own risk.

HCP EDUCATIONAL · Not a device · Independently review · Use at your own risk